If you need to use a longer VISCA cable than the one provided with the Teamline room system, refer to the following cable requirements:

  • VISCA cables are available in crossed and straight-through configurations; Teamline room systems require straight-through cable
  • The plugs should seat well into the socket on the rear of the room system. On some room systems, the sockets are slightly recessed behind the back panel; take care that cables with larger shrouds on the connectors are seated correctly into the sockets (you may need to modify the cables)

Pinout

The following diagram shows the pinout for the Camera Control connector on the rear of the Teamline room system:

Diagram of the camara cable pinout

Pin Function Direction on the Teamline system
1 MD Output
2 IR Input
3 GND
4 TX Output
5 GND
6 RX Input
7 DTR Output
8 DSR Input